Saturday, March 19, 2016

Simplified Superlink Interface!

Here is part 4 of the Cryocooler Saga! You can see Part 1 and Part 2 and Part 3 also.

tl;dr - Here's a program for interfacing with a Superconductor Technologies Superlink

There's a lot of data pumped out by the cryocooler while it's operating, including various temperatures, voltages, power consumption, et cetera. Unfortunately, I could only access that data through the manufacturer's software, which won't run on anything beyond Windows XP. I have a 10 year old laptop that will run it, but I mean c'mon, it's a ten year old computer. I'm not sure how much longer ol' Speed Turtle here is going to keep on staying critical-failure-free.

High Technology
Besides, I'd ultimately like a way to replace the cold-side temperature measurement the cryocooler uses with a different device, which would be greatly simplified if the device measuring the temperature can see what it's transmitting to the Superlink.

The System Status Portal software turns out to be a pretty face for the serial back-and-forth between the computer and the Superlink. The link runs at 19200 baud, 8 data bits, zero parity, no flow control. I ran a serial monitor program while the computer had the software open and talking to the Superlink, and it showed that the back and forth looked something like this:

Request: 3/13/2016 9:59:32 PM.57264 (+0.2567 seconds)

 3C 53 59 20 4F 50 3D 22 4F 4B 22 2F 3E 0D 0A      <SY OP="OK"/>.. 

Answer: 3/13/2016 9:59:32 PM.57264 (+0.0000 seconds)

 3C 53 59 20 4F 50 3D 22 4F 4B 22 2F 3E 0A         <SY OP="OK"/>.  

Request: 3/13/2016 9:59:32 PM.60364 (+0.0000 seconds)

 3C 54 4D 20 4F 50 3D 22 47 54 22 20 4C 43 3D 22   <TM OP="GT" LC="
 43 52 22 2F 3E 0D 0A                              CR"/>..         

Answer: 3/13/2016 9:59:32 PM.60364 (+0.0000 seconds)

 0D 3C 54 4D 20 4F 50 3D 22 47 54 22 20 4C 43 3D   .<TM OP="GT" LC=
 22 43 52 22 3E 30 20 30 20 31 38 20 33 35 3C 2F   "CR">0 0 18 35</
 54 4D 3E 0A                                       TM>.            

Request: 3/13/2016 9:59:32 PM.63364 (+0.0000 seconds)

 3C 54 4D 20 4F 50 3D 22 47 54 22 20 4C 43 3D 22   <TM OP="GT" LC="
 41 43 22 2F 3E 0D 0A                              AC"/>..         

Answer: 3/13/2016 9:59:32 PM.63364 (+0.0000 seconds)

 0D 3C 54 4D 20 4F 50 3D 22 47 54 22 20 4C 43 3D   .<TM OP="GT" LC=
 22 41 43 22 3E 41 43 42 20 33 20 41 43 39 20 31   "AC">ACB 3 AC9 1
 30 3C 2F 54 4D 3E 0A 0D                           0</TM>..    

The interaction consists of query strings sent by the computer that are returned with the data requested. Pouring through the decompiled code for the System Status Portal (what can I say, I live a wild life), I managed to figure out which query strings returned the data I was interested in. Turns out, if you want to find the cold side temperature and cooler rejection temperature, you ask:

<TP OP="GT" LC="MS"/>

which is responded to with something like:

<TP OP="GT" LC="MS">F 6D80 3BE8 4D60 3C78</TP>

Each of those five hex numbers in the middle there correspond to five different measurements it's returning. Turns out the cold side wide range temperature is the second one (6D80) and the cooler rejection temperature is the third one (3BE8). That hex number is pretty meaningless, though. Pouring through more of the System Status Portal code, I found the formulas it used to convert those numbers to actual temperatures. The formula is:

Temp = (5 * (hex string converted to decimal)/32768 - Offset)/Gain

where for the cold wide range temperature, the offset is 5.814 and the gain is -0.01559. There's a different offset and gain for the rejection temperature and the other temperatures returned. Convert the two-letter parts of the query string ("TP", "OP", "LC", "MS") to their ASCII equivalent hex codes (TP=5450) and then convert that to a decimal number (hex 5450 = 21584), and search the System Status Portal code for that decimal number to work through the logic to find which data points are revealed by which query strings!

Similarly, the cooler power draw can be elucidated with the proper query string and formula, as can every other measurement that shows up in the System Status Portal. In addition to reading measurement values, the System Status Portal can also change the operating state of the cooler, switching it between manual mode where the cooler can be shut off and automatic mode, where the cooler will automatically ramp up power as the cold side temperature declines, keeping the cooler within its safe operating limits. This is accomplished with another query string,

<TP OP="ST" LC="SM">1 4</TP>

will set the cooler to manual shutdown mode, while

<TP OP="ST" LC="SM">0 4</TP>

will turn it back to automatic mode.

I needed an excuse to brush off my infantile Python skills, so I wrote a user interface that will allow you to see the cold side wide range temperature, cooler rejection temperature, cooler power, and status. You can also toggle between Manual Shutdown mode and Automatic mode, so you can shut down the cryocooler safely without the System Status Portal program. I've loaded the Python code to github - you'll need Python installed (I used version 3.5), along with the Tkinter and pySerial libraries to run it. I've only tested it on my Windows 10 computer, but it appears to work pretty well. Here it is on Github. There's a lot of room for improvement and expansion, so if you want to add functionality, go for it!




I next plan to replace the cold side temperature measurement with an external thermocouple, using an Arduino to simulate a resistance to send the temperature measurement to the Superlink. I'll then use the serial handshake to allow the Arduino to talk to the Superlink to read the temperature it's trying to simulate, allowing it to precisely control its output to make sure the Superlink is seeing the same temperature it is.

Friday, February 12, 2016

A goofy 1000 psi air compresor...using a pressure washer

Hey, not all projects have to be practical, right? Sometimes, you just start putting things together and end up with something like this:


For reasons that ultimately led to my cryocooler purchase, I wanted to have a source of quite high pressure (~1000 psi) air. Most ordinary utility air compressors top out at about 150 psi, which, working in the oil and gas industry, seems like small potatoes. I wanted some pressure, I'm talking ANSI 600 class at least. In my line of work, we use devices called blowcases to pump liquids using high pressure gas. They're convenient when you need to pump a liquid to relatively high pressures and don't have any utility electric power, but do have a source of high pressure gas. I figured I could do this in reverse, taking a source of high pressure liquid to pressurize a gas.




The "compressor" works by allowing gas from a lower pressure source (a shop air compressor capable of 150 psi discharge pressure) to enter the compression chamber. Water is then pumped in from the bottom, compressing the gas and allowing it to flow into a reservoir. Once the water reaches a high-level sensing line, the flow of water in is stopped and the water is drained out the bottom. The cycle is then repeated until the pressure in the reservoir is the desired pressure. The level is sensed by a magnet wire inserted into the chamber through a hole drilled in a plug, and then epoxied in place. An Arduino was used to sense when the resistance between the chamber walls and the sensing wire fell, indicating that the water level had reached the wire (good thing mildly impure water is a good conductor). The Arduino then switches a pair of automated valves via a solenoid valve to shut off flow from the pressure washer and drain the chamber. After a set time, the valves are switched again and the cycle repeats. Here's a terribly shaky video explanation of the contraption. Yes, that (was) my kitchen. No, that floor no longer haunts my dreams. Never buy a house, but that's another anthology.



A nice thing about living in an oil field (there are a small handful) is that the local plumbing supply store sells Schedule 80 A106 Grade B pipe capable of withstanding well over 1000 psi and 3000 psi rated fittings. I bought some 2" pipe nipples, and couplings, bushings, and tees. From McMaster Carr (truly the greatest retailer in the solar system), I bought some 1/4" NPT fittings and steel tubing. Off of ebay, I found some reasonably priced 1000 and 2000 psi rated ball valves equipped with pneumatic actuators and an Asco solenoid valve. One happened to be installed as fail open and the other as fail closed, which made it possible to control both valves with the single solenoid valve (although it's pretty easy to switch the fail position on pneumatic actuators of this type). Hooking the pressure washer up to the 2000 psi actuated valve and using the 1000 psi valve to drain the chamber, the contraption actually worked to get up to beyond 900 psi!

pics or it didn't happen

Granted, it did turn out to be quite a pain in the butt to set up, and the time to pressurize the air was quite long, so why in the world of alabaster did I want to do this? At the time, I was thinking the easiest way I could generate liquid air was to allow high pressure air to go through a Joule Thompson expansion to cool it down to liquefying temperatures. However, to JT straight to a liquid, you need to get on top of the liquid envelope on the pressure-enthalpy diagram, that is to say pressurize it beyond its critical pressure, which for air is about 37 atmospheres or 550 psi. After that, you still need to chill it down to about 150K and then JT it to get it into the liquid envelope, but I figured 150K would be easier to achieve than 80K. Turns out, not really, I never got a way to get to those temperatures until I got my cryocooler, which could get all the way to 80 K anyways. It was a fun proof of concept nonetheless.

Thursday, January 7, 2016

Superlink teardown

Here is part 3 of the Cryocooler Saga! You can see Part 1 and Part 2 also.


So what does all that stuff in the box do? What's necessary to keep it running happily along and what can be cut out? Let's figure it out!

First off, what do we have under the hood? Here's a rough labeling of some of the important parts:

Click for big!
Wow, that's crammed in there. Nice!

In addition to the cryocooler that's the reason I bought this whole shebang, there's a power and control circuit board, a dewar containing the superconducting elements (connected to the cryocooler with a vacuum flange, presumably to maintain a tight seal on the cold side to minimize leakage), and a cooling fan that forces air through the cooling fins on the heat-rejection location on the cryocooler. There's also a jumble of RF wires that presumably connect to whatever it's supposed to be super-filtering. Those can be disconnected from the dewar by loosening each of the screw connections.

The cryocooler is held in position with two machine screws near the cooling fan, and the dewar is held in place with a pipe clamp. The cryocooler screws can be easily accessed by removing the cooling fan first, as shown below. First, I removed the dust filter in front of the fan. This makes visible the four screws holding the fan in place.





Once the fan is removed, the screws can be removed by putting an allen wrench (or a star drive, as I used) through the fan hole.



Next, I disconnected the back plate with all of the RF wires from the base of the unit by removing a few screws.

The two on the bare steel tab. Ditto on the other side.

Next, I disconnected the clamp holding together the vacuum flange connecting the cryocooler and the dewar near the heat rejection fins, and completely loosened the pipe clamp holding the dewar down.



This allowed me to remove the entire cryocooler-Dewar assembly, or more easily, separate the two and take them out separately. The cryocooler's cold head is covered in a thermal paste.



The dewar looks to be of an interesting construction - it has a piece that slides up the cold head past the flange, which appears to be welded on the end. My guess is that it's two pipes with a small gap between them in which there's a vacuum that further insulates the cold head from the heat rejection area. Maybe someone who knows better can correct me.





Before removing the cryocooler, you'll need to disconnect a few wires from the circuit board. Here's an annotated photo of what's going on there. I disconnected the rejection temperature sensor (bottom right) and the cryocooler power connector (bottom left) and loosened the cable ties holding the wires in place in order to remove the cryocooler. I also needed to disconnect the wire bundle to the dewar on the right in order to remove it.

Click for legible
:

As mentioned in the photo and a previous post, the only signals needed to run the cooler are the rejection temperature sensor and the cold-side temperature sensor from the dewar (which is the pin pair the fourth from the bottom on the wire harness). Some of the other pin pairs show a voltage difference while the board is running, but I can't figure out what they're doing, and it doesn't seem to throw any faults if they're disconnected.

Me trying to figure out what the pins do. Turns out, not much that I need worry about, maybe?

Next up: Spoofing that temperature signal so I can use my own cold side temperature sensor!




Monday, December 28, 2015

Liquid air!

Here is part 2 of the Cryocooler Saga! You can see Part 1 and Part 3 also. 


It works! Here's my first liquefied air! I'd removed the cryocooler from the Superlink and mounted it in a wooden frame to hold above a thermos to collect the air in. Here's how I put it together.

After removing the cryocooler from the Superlink, I built a wood frame to allow the stock fan on the Superlink to blow air through the cooling fins on the heat rejection side. He's a scrappy fellow.

This thing's walls are probably more sound than some of them in my house. Not that that's saying much.

The hole in the base is (approximately) the size of the cooling fins, forcing air to flow through them.

I made a trap door on the bottom to divert air blowing out the bottom away from the cold finger. It's just a few pieces of aluminum sheet screwed to the wood, with 1/8" luan for the trap door. The luan sheets can be separated to insert the cryocooler flange, then closed around it to divert most of the air away. I didn't make any special effort to make it a tight seal. We aren't trying to freeze all of Gotham City here, absolute efficiency isn't really one of my goals at the moment.



The cooler's control program requires that the cold side temperature be measured to control the power input to the cooler. I figured out that the only pins on the wiring harness that goes to the Dewar that tell the control board what the temperature is are the pair on the fourth from the bottom. The control board appears to have a constant-current circuit that attempts to put 0.1 mA through the pins and measures the voltage. At ambient temperature, the resistance is roughly 5.6 kilohms, so my best guess is that the temperature sensing element in the dewar is a thermistor that is specifically designed for accuracy at about 80K. Putting a 10K potentiometer between the pins allows you to gradually lower the "measured" temperature of the cold side for the control board to allow it to cool down. I plugged a couple stackable headers into the connector to use as sacrificial pins so I don't damage the original circuit board's pins.


I don't want to damage the cooler by trying to ramp it down too aggressively though, so I tried a few ways to measure the temperature of the cold head. A kitchen thermometer gave up at about -40 degrees. I had a Type K thermocouple with a MAX6675 amplifier, but that chip can't read below zero C. I ended up buying a MAX31855K from Sparkfun, which allegedly can go to -200 C, right about where we want it. More on that later. I put a cheapo coffee travel mug under it and fired'er up! 


Aaaaand, not much happened, other than the mug sweating like a cynophobe at the Westminster Kennel Club. Turns out that insulation is a feature that some mugs lack, albeit they compensate with sweet wood paneling. I tried supplemental insulation (a layer of bubble wrap, four layers of floor underlayment insulation, and a towel for good measure), and that allowed the cold finger to get down to 133 K as measured by the newly improved thermocouple, but nothing was in the mug upon removing it from the cooler.




I broke down and bought the mug that claimed the longest time to keep its contents cold/hot that was available at my local Wally World, which ended up being a Thermos brand. I put it in and cranked it down. It hit a brick wall about 133 K also, which I though was strange, because the temperature had been dropping fast when it hit that temperature. I let it go about half an hour before guessing that perhaps the thermocouple calibration wasn't quite on and perhaps it was indeed in the 80-90K range and was stuck because it was condensing air.



Sure enough, when I took it off, I had a good bit of liquid in the bottom! Cold diggity dogg!


A few improvements in the works - I plan to calibrate the thermocouple by placing it in the original Dewar and then cooling it down with liquid air and monitoring the "real" measured temperature as reported by the cooler board when connected to the dewar to make a calibration curve for this thermocouple. Ultimately, I'd like to send a proper signal back to the control board so it can control the cooldown itself, by either finding the proper thermistor to connect or spoofing the signal to the control board. I also plan to fabricate some sort of assembly to decently isolate the cold head and thermos from the atmosphere, so I can introduce gases I want to liquefy into the thermos without air contamination.


Sunday, December 6, 2015

Cryocooler

HO-LY-FA-ZO-LI. I'm on the brink of accomplishing one of my long-time desires - having a device capable of creating liquid nitrogen OUT OF THIN AIR (or 253-foot-above-sea-level air at least). Why? Why not, of course! How? Let's go there.

I'm now the proud owner of a Stirling cycle refrigerator (or cryocooler) capable of cooling something down to the neighborhood of 77 Kelvin, or 320 degrees Fahrenheit below zero. Assuming you're reading this on Earth, your atmosphere consists of something like 78% nitrogen, 21% oxygen, and 1% argon and other gases. By cooling down air to somewhere between 77 K (nitrogen's boiling point) and 90 K (oxygen's boiling point), air will begin to condense into a liquid mixture of nitrogen and oxygen. Trouble is, the coldest day in the chilling depths of South Texas winter is about 280 K, or about 200 degrees K or C too hot. Luckily, at the intersection of cell phones and superconductors, there was reason for a company called Superconductor Technologies to manufacture a fine piece of thermodynamics known as a Stirling Cycle Cryocooler.



Now that everybody has fourteen cell phones and smart watches apiece blasting out radio waves constantly, cell towers must be able to filter out all of the noise in order to provide service for each device. It turns out, for reasons I won't even pretend to give a hilariously naïve explanation of, that superconductors can help do a fantastic job of filtering only the target radio signal and amplifying it. Back in the 80's, some sharp grad students discovered that certain materials lose all resistance at temperatures as high (hah) as liquid nitrogen's boiling point. This finally culminated in the purpose for the folks at Superconductor Technologies to attempt to create a compact, reliable, low-ish cost refrigeration device capable of getting down to those temperatures, in order to cool superconducting filters. They did it so well that today you can buy ten year old devices on Ebay for $600 or so that are still perfectly functional. The ghost of Carl von Linde is probably beaming with joy. That these pieces of surplus telecom equipment had within them these cryocoolers was discovered by tinkerer extraordinaire Ben Krasnow and documented over at his blog, which is where I got my inspiration.

I bought a Superlink 850 superconducting filter off of ebay, which includes a Stirling cryocooler rated up to 150W input power. Like any refrigerator, it has a hot end and a cold end. The working fluid is high pressure helium. The piston and displacer are shuttled back and forth by a solenoid linear motor. Here's a paper that describes the workings.

The Superlink - some disassembly required

When I first received the cooler, I powered it up with a variable power supply (it needs about 27VDC to run) but the unit didn't cool. The seller was able to put me in touch with another cryocooler enthusiast who was able to help teletroubleshoot the problem down to a blown power transistor on the control board - shout out to Andrew for graciously donating his Friday night helping out a total stranger.

The toasted transistor kindly left a chalk outline around its dead body to identify himself.
After the seller shipped a new board, the cooler worked just as intended. Besides the troubleshooting, Andrew also offered some valuable tips about the cooler's operation, including a suggestion to use a 36V power supply adjusted down to the acceptable range of the cooler. I bought one off ebay capable of 11 amps output and able to adjust down as low as 28V out of the box, which is in the acceptable input voltage range.

I have some work to do to get it into a functioning air condensing machine, but it'll be fun along the way!

(Edit: Here's Part 2 and Part 3 of the Cryocooler Saga. Part 2 is pretty darn cool!)

Tuesday, August 4, 2015

Supercritical Propane

If Superman were a thermal fluid, he'd be a supercritical one! Supercritical fluids are one of those fascinating things in nature that you never see in everyday life and therefore for which our intuition can just fail miserably. You'd never think that at some point, a fluid would have an identity crisis and a gas would stop being a gas and a liquid would stop being a liquid, and the fluid would decide to mish mash up properties of both into a completely different phase.

I've seen (and done) supercritical CO2 before, but I'd never seen supercritical propane attempted. Propane's critical point is 97 degrees C (206 F) and 42 atmospheres pressure (616 psi). It's a little hotter and a little lower pressure than CO2's critical point, but the temperature is tantalizingly close to the boiling point of water, meaning it's a piece of cake to attain - just drop a sample in a vat of boiling water! The 42 atmospheres pressure is a little trickier - luckily I had sitting around a 1/2" 2000 psi rated ball valve (from ebay) and - even better - a 1750 psi rated sight glass! It's no fun if you can't see it!


I transferred some propane into this contraption by connecting it to a small propane torch tank with an adapter that had 1/8" NPT threads. I opened the propane tank to the contraption and then disconnected and depressurized it to purge a good bit of the air out. I reconnected the tank and then dunked the sight glass end in a cup of ice water, which reduced the pressure on that end and caused propane to flow from the cylinder into the valve/sight glass combo. I let it flow in until the chamber between the ball and the sight glass was about half full of liquid propane. Closing the ball valve trapped the liquid propane on the sight glass side of the valve, and I disconnected the propane tank.




I filled a one liter flask with water and wired up a harness to suspend the ball valve in the water. Heating the water subsequently heated the propane in the valve. Once it hit about 190 F, the propane in the chamber began to boil. As the temperature rose, the liquid fraction appeared to decrease, and finally, about 207 F, it disappeared completely - supercritical! At that point, the vapor and liquid phases decided to settle their differences like Rocky and Apollo, and they should have the same surface tension (none), density, should be miscible with other fluids, et cetera. They become the best of friends, alike in every way. But then Ivan Drago killed... ok this analogy is getting out of hand.


Here it goes! I apologize for the nerdy commentary - actually no, I take that back because this is awesome.

So what's really going on in here? As the pressure and temperature get closer and closer to the critical point, the differences in all properties between the gas and liquid phases start to get smaller and smaller. The density of the liquid phase decreases, while the density of the gas increases. The viscosities likewise approach each other. Then, suddenly, the difference between the two vanishes abruptly. Through the transition, it drags a couple of properties of each. For instance, the surface tension, which is basically what makes a liquid a liquid, disappears, making the fluid gas-like in that sense. The fluid has no tendency to stick together anymore, and is completely miscible (mix-able) in any proportion with any other gas or supercritical fluid. Some liquid-like properties are dragged through too - a supercritical fluid can have strong solvating power, dissolving other substances. These weird properties lead to many of the ways supercritical fluids are used, like in dry cleaning, for their strong solvating power - making them good at getting rid of oily stains on clothes, mixed with their lack of surface tension - making them able to get into all nooks and crannies to dissolve tough-to-get-at stains. Best of both worlds - ain't it great when you can have it all? Sometimes Mother Nature throws us a bone - and looks damn fine doing it in that squeaky clean getup.

Edit: Here's a slightly better video of the transition



Sunday, August 2, 2015

DIY Rotovap

I wanted to do some vacuum evaporation projects, so I built a DIY rotovap. This certainly ain't a laboratory grade, strong solvent resistant, low leakage setup, and it has very few speed settings (currently "On" and "Off"), but it does indeed work at allowing vacuum distillations to be carried out, recovering a distinct overhead product and bottoms product.


The evaporation chamber is a Mason jar with a 3/4" x 1/2" PVC bushing epoxied to the lid. I used two electrical conduit locknuts to hold the fitting in place while the epoxy set.



To rotate the evaporation chamber, I mounted an electric motor in a wood frame and mounted a section of 1/2" CPVC pipe in a pillow block bearing. I connected the bearing to the motor shaft with a series of small plastic gears.



I left one section of the CPVC un-cemented on top of the bearing, to allow the pipe to be removed from the bearing. Adding a bit of teflon tape to the pipe before pressing it into the coupling gives a "good enough" vacuum seal.


The heating method for the Mason jar originally gave me trouble. At first, I considered a laboratory hot plate, but was put off by their high cost, and the difficulty I expected to experience in getting uniform heating on the jar. I then realized that I was an idiot, as I already had an electric skillet that I could put a pot of water on to uniformly heat the jar. I tried this, but was less than impressed with the amount of heat I could transfer into the jar. It was also a cumbersome setup. While at the store looking for a smaller, higher heat output hot plate, I realized I was a double mega idiot, and that I had a crock pot that could do exactly what I wanted, with a pretty good heat output to boot. What's more, it's relatively easy to control the temperature in the crock pot over the timescales on which the distillation runs by adjusting the heat setting on the pot.

The next tricky part was the method to give a vacuum-tight seal while allowing continuous rotation. The method I ended up on was to use a compressed air quick connect fitting. These are available at any hardware store at a low cost (about $5 for the male and female components). I used a 1/4" fitting. It does have a rather small restriction through the fitting which isn't ideal for vacuum pressures, but again it works "good enough" for this non-high-vacuum setup. It does have a fair bit of resistance to rotation, which is why the motor I ended up using was so large - a first draft used a smaller motor that couldn't overcome the resistance of the quick connect fitting. The motor I used has a gear reducer that reduces the rotation rate to about 60 rpm, giving it high enough torque to overcome the resistance. It remains to be seen how well the quick connect fitting holds up with use, but they're pretty darn cheap and could be replaced easily.

The overhead business side is the handled by a filter flask. In operation, the flask sits in a bath of ice water to condense the overhead vapors and collect them. This is the only actual piece of lab glassware in the entire setup, and I used it because I had one on hand. I could just as well have modified another Mason jar to the task. A section of PVC extends down nearly to the bottom to force the heated vapors to come into close contact with the cold walls. If the flow didn't contact the vessel walls, a good portion of the overhead product would go straight out the side port to the vacuum pump, which would be bad for the pump and bad for the recovery of the overhead product.


I originally had some difficulty with the sealing element between the filter flask and the PVC, but then fortuitously discovered that a 3/4" PVC compression coupling's rubber gasket is perfectly sized for this filter flask's mouth diameter. A flexible hose connects the filter flask to my Harbor Freight vacuum pump.

Here's a dry run showing everything working together:



Here's a hot run with the first generation (aka dumb) heating method for the boiling jar.


My first run was to distill some tea - I wanted to make some tea concentrate to use in other recipes. It was a technical success, in that I was able to concentrate the tea to a much stronger concentration, with an overhead product that tasted like plain water. The concentrate was decidedly non-tasty, though, so it might not have been a recipe success. I'm not sure if this is because I got the fluid too hot during the distillation - the whole point of vacuum distillation is that you can boil the liquid at a lower than normal temperature. I plan to try again, we shall see if tea-asty product will result!